Absorption Characteristic
Material constant parameters quantify the fraction of an incident X-ray beam that is scattered or absorbed per unit of area mass. The mass attenuation coefficients of the constituents in a printed circuit board govern the contrast in digital X-ray images. These values vary depending on the chemical composition of the material and the energy spectrum of the radiation source.
Heavy metals such as copper and lead possess high coefficients, whereas organic epoxy resins have much lower values.
Thickness Dependency
Effective contrast between copper traces and the underlying fiberglass substrate relies on the difference in these absorption constants. By normalizing the linear attenuation by the material density, mass attenuation coefficients remain independent of the physical state of the substance. This consistency allows inspection software to calculate the expected signal loss for any combination of copper weight and substrate thickness.
Defect Identification
Solder joint inspection machines utilize these values to determine the volume of alloy present in a ball grid array. When X-rays pass through the joint, the intensity profile on the detector corresponds to the thickness of the solder along the beam path. If the mass attenuation coefficients are programmed accurately, the software can locate void defects within the joint by measuring localized increases in transmitted radiation.
This automated calculation prevents defective boards with insufficient solder or hidden voids from leaving the assembly plant.