Contact Configuration
Four-wire measurement logic is approximated by bringing sense and source lines together at the probe tip rather than at the test point itself. Using a pseudo kelvin arrangement reduces the error introduced by lead resistance while using standard two-point probe heads. This approach is common in automated flying probe testers where the physical space on a small pad is insufficient for two separate probes.
Accuracy Limitation
The resistance of the wiring from the meter to the probe head is eliminated from the measurement. However, the contact resistance between the probe tip and the test pad remains in the circuit. Because pseudo kelvin probes share a common tip, they cannot compensate for the interface resistance at the point of contact.
Measurement accuracy is therefore limited to the stability and magnitude of the contact resistance, which might vary based on pad oxidation or probe pressure.
Selection Logic
Manufacturers choose this method when the expected resistance of the component is much higher than the contact resistance of the probe. It provides a marked improvement over simple two-wire testing without the mechanical complexity of dual-needle assemblies. Measurement errors typically remain within acceptable limits for most manufacturing defects like open circuits or wrong components.