Emission Scanning
Diagnostic techniques capture the electromagnetic field distribution in the immediate vicinity of a circuit board. Utilizing spatial near field mapping identifies the specific components or traces that are responsible for excessive radiation. This process uses a robotic arm to move a small probe in a grid pattern above the surface of the assembly.
It provides a visual representation of the hot spots where the electromagnetic energy is most intense.
Probe Mechanism
Selection of the correct probe depends on whether the goal is to measure electric or magnetic fields. Loop probes detect magnetic flux from currents, while monopole probes are sensitive to the voltage on the traces. As the spatial near field mapping probe moves, the system records the frequency and amplitude of the signals at each coordinate.
This data is then processed to create a color coded map that correlates the emissions with the physical layout of the board. High resolution probes allow for the isolation of noise from individual pins on a fine pitch integrated circuit. The software must compensate for the frequency response of the probe to ensure that the displayed amplitudes are accurate.
Analysis Scope
Troubleshooting is the primary use for this type of data. If a board fails far field compliance testing, spatial near field mapping helps locate the leakage point without needing a full anechoic chamber. The resolution of the map is limited by the size of the probe tip and the distance from the board surface.
It cannot replace final compliance testing but reduces the number of design iterations required to pass.