Delay Screening
Structural test methodologies verify high-speed digital circuit operation by detecting slow voltage transitions that cause timing failures at system operating frequencies. Automated test equipment utilizes transition fault testing to catch localized spot defects that introduce small delay anomalies without causing total functional logic failure. The fault model places a slow-to-rise or slow-to-fall defect target at every node within the gate-level netlist.
Defect screening operates by launching a logic transition at a target node and capturing the response after a timed clock period.
Structural Activation
At-speed testing applies two consecutive clock pulses during test execution to activate and measure dynamic node transitions. An initial clock pulse launches a state change from an initialized scan cell into surrounding combinational logic. A subsequent clock pulse captures the resulting state into a destination register at system operating frequency.
Automatic test pattern generation software calculates launch and capture vector pairs that propagate delay faults along critical paths. Path delay variations caused by resistive vias and partial gate oxide breakdowns are caught by these timed vector sequences.
Pattern Coverage
Transition fault models generate significantly larger test pattern sets than static stuck-at fault models. Scan compression hardware compresses test patterns to fit within automated test equipment memory boundaries. High transition coverage ensures robust screening of timing-critical speed defects.