Planar Attenuation
Non-destructive inspection methods relying on planar transmission attenuation generate two-dimensional projections of internal electronic structures. Projection imaging using 2d radiography directs x-ray photons through printed circuit board assemblies onto a digital detector panel. Dense materials like tin-lead or lead-free solders attenuate rays heavily, creating high contrast against surrounding epoxy resin and copper foil.
Void Quantification
Surface mount assembly standards set explicit acceptance thresholds for interfacial voiding in ball grid arrays and bottom terminated components. IPC-A-610 caps total solder void area within a single BGA ball projection at twenty-five percent during 2d radiography inspection. Radiographic shadows from components mounted on opposing board surfaces regularly obscure top-layer solder pads, requiring operators to calculate net void area by subtractive grayscale analysis.
Automated software calculates total void area ratios against total solder pad footprint, flagging units that exceed specified IPC thresholds. Higher solder volume or thick copper planes attenuate photons more intensely, requiring calibration of tube voltage and exposure time to maintain measurement linearity.
Resolution Limit
Micro-focus x-ray sources provide structural resolution suitable for detecting macroscopic assembly defects like solder bridging and missing solder bumps. Sub-micron cracks and micro-voids under three micrometers remain invisible under flat planar exposure. Complex multi-layer assemblies with stacked die structures demand three-dimensional computed tomography when overlapping planar structures obscure individual interconnect layers.