Circulating Current
Unintended electrical paths formed by multiple return connections create electromagnetic interference in signal cables. A coaxial ground loop occurs when the outer conductors of cables are bonded to chassis at different potentials. Potential differences between these points drive current through the shield, which couples into the signal wire.
This mechanism degrades the signal to noise ratio.
Interference Mechanism
Stray magnetic fields induce low frequency voltages in the loop formed by the signal cable and the shared ground reference. Because the shield has finite resistance, the induced current produces a voltage drop that adds directly to the signal. This effect is pronounced in high gain analog circuits or unbalanced digital interfaces where the reference potential must remain stable.
Common mode rejection becomes impossible once the noise is converted to a differential voltage at the receiver input. Inductive coupling from power transformers often creates the primary source of this interference.
Suppression Method
Breaking the path using galvanic isolation or common mode chokes prevents the formation of the current loop. Designers often use differential signaling to ensure that the return path is tightly coupled to the signal conductor rather than the chassis ground. Balanced connections effectively ignore the noise voltage present on the shield.
Ferrite beads applied to the cable also increase the impedance at high frequencies to dampen circulating currents.