High Voltage Breakdown
Dielectric failure events in high-voltage circuit assemblies involve localized electrical discharges that only partially bridge the insulation between conductors. This localized discharge, known as partial discharge, occurs within voids or cracks in the laminate where the electric field exceeds the local dielectric strength.
Insulation Degradation Process
The occurrence of partial discharge creates ozone, ultraviolet light and chemical byproducts that degrade the surrounding epoxy-glass substrate of the printed circuit board. This chemical breakdown enlarges the existing microvoids and creates conductive pathways, which eventually leads to a complete dielectric breakdown and short circuit. Because these discharges occur at voltage levels below the final breakdown voltage, they are difficult to detect during standard insulation resistance tests.
Manufacturers of high-voltage boards use specialized high-frequency detectors to monitor the transient electrical pulses generated by these micro-discharges during production testing.
Failure Prevention Strategy
Preventing these discharges requires optimizing the lamination process to eliminate air bubbles and ensuring that internal copper layers have rounded profiles to minimize field concentration. These board fabrication improvements are accompanied by applying conformal coatings to seal exposed solder joints and eliminate surface discharges. Designers use conservative trace spacings and choose laminate materials with high resistance to voltage tracking.