Mechanical Motion
Lateral movement of a test probe after initial contact breaks through surface oxides to establish a stable electrical connection. Defining the scrub vector involves setting the angle and distance the probe tip travels across the target pad. This controlled sliding action is a standard feature in flying probe testers and wafer probers to ensure repeatable measurements on contaminated or oxidized surfaces.
Contact Quality
A sharp tip follows the programmed scrub vector to create a fresh metal-to-metal interface. This action is necessary for boards that have undergone multiple reflow cycles or have remained in storage. The length of the vector must be balanced to provide enough cleaning without damaging the thin plating of the pad.
Overly aggressive scrubbing can gouge the copper or push debris into the contact area. Modern equipment allows for sub-micron adjustment of this movement to accommodate soft gold or organic solderability preservatives.
Surface Impact
Inspection systems look for the mark left by the probe to verify that the alignment was correct. The scrub vector leaves a visible track on the solder or gold finish of the landing area. Analysis of these marks helps engineers tune the pressure and travel distance for different surface finishes.