Dimensional Check
Measurement of the center to center distance between adjacent 3D pixels in a computed tomography scan confirms the scaling accuracy of the system. Successful voxel pitch verification ensures that the physical dimensions of internal features, such as buried vias or solder voids, are reported correctly. This process is essential for meeting the inspection requirements of high reliability aerospace and medical electronics.
Volumetric Accuracy
Determining the correct voxel size requires scanning a reference object with features that are known to a high degree of precision. The voxel pitch verification routine compares the number of voxels between two points in the reconstructed image to the actual physical distance on the phantom. If the software reports a distance of 10.1 millimeters for a 10.0 millimeter standard, the scaling factor must be updated in the reconstruction engine.
Correct calibration must account for the magnification level, which changes based on the distance between the x-ray source and the detector.
System Drift
Changes in the position of the x-ray tube or thermal expansion of the mechanical stages can cause the spatial resolution to fluctuate over time. Regular voxel pitch verification detects these subtle shifts before they result in the rejection of good parts or the acceptance of defects. Most industrial standards require a daily check to be performed at the start of every shift or after any change to the hardware configuration.
Documentation of these results provides a traceable record of the measurement system capability for audit purposes.