Inspection Technique
Measuring electromagnetic emissions in close proximity to a circuit board surface identifies localized sources of interference before full chamber testing. A near field scan uses small magnetic or electric field probes to map the radiation intensity across the assembly. This method provides high spatial resolution by capturing evanescent waves that do not propagate into the far field.
Spatial Resolution
Probes move in a controlled grid across the PCB to create a visual heat map of the electromagnetic fields. The near field scan allows for the separation of noise sources that would appear as a single broad emission in a far-field test. Resolution is limited by the size of the probe tip and its distance from the board surface.
Smaller probes provide more detail but have lower sensitivity. This detailed mapping is useful for verifying the effectiveness of shielding or the placement of decoupling capacitors. Automated scanning systems ensure repeatability by maintaining a constant probe height throughout the measurement process.
Diagnostic Value
Early identification of emission hot spots reduces the number of design iterations needed to pass certification. Results from a near field scan correlate with far-field performance but provide the specific location of the failure. This information is used to modify the layout or add filtering where it is most needed.
It also helps to verify that no unintended coupling occurs between sensitive analog circuits and high-speed digital sections.