Thermal Growth
Increase in the total volume of a resin system as it undergoes heating defines the physical displacement that occurs within a laminate. Measurement of resin volumetric expansion is critical during the transition through the glass transition temperature where the rate of growth increases sharply. This property determines the pressure exerted on the copper traces and plated through-holes from within the board.
Physical Strain
Molecular motion within the polymer chains accelerates as heat energy is absorbed during the soldering or lamination process. Significant resin volumetric expansion in the z-axis direction puts the copper barrels of the vias under tension. Because the resin expands much faster than the glass fibers or the copper plating, the resulting strain can lead to the fracture of the internal connections.
Thermomechanical analysis is used to quantify this expansion and ensure the material is compatible with the intended thermal environment.
Integrity Risk
Reliability of the final product is directly tied to the ability of the copper to withstand the repeated cycles of growth and contraction. Excessive resin volumetric expansion during multiple reflow cycles often leads to corner cracks in the plating or delamination at the interfaces. Designers select materials with high filler content to mitigate this effect by reducing the overall resin percentage in the composite.
Boards intended for harsh environments require resins with a high glass transition temperature to delay the onset of the rapid expansion phase.