Joint Resistance
Electrical resistance to the flow of current across a joint in a shielded enclosure. In electromagnetic compatibility design, seam impedance determines how much radiation leaks through gaps. Low values are achieved through contact pressure.
This impedance reduces shielding effectiveness.
Interface Continuity
Mechanical fasteners provide the force needed to bring the two surfaces together, but the microscopic roughness of the metal prevents a perfect electrical connection. The seam impedance is essentially the sum of the contact resistances at each point of touch. Conductive gaskets fill these microscopic gaps and provide a continuous path for the return currents flowing on the inside of the shield.
Without these materials, the gap acts like a slot antenna and radiates energy.
Frequency Dependency
At higher frequencies, the skin effect limits the current to the very surface of the metal, making the quality of the finish more important. The seam impedance can vary significantly across the length of a joint if the fasteners are spaced too far apart. Engineers use a maximum spacing of one twentieth of a wavelength to maintain a consistent low-impedance path.
Testing this property usually involves measuring the shielding effectiveness of the entire enclosure in an anechoic chamber.