Cross Sectioning
Non-destructive volumetric imaging systems isolate horizontal slice planes within multi-layer circuit boards and hidden solder joint arrays. Radiographic imaging techniques capture synchronized projection angles to separate top-side solder joints from bottom-side components on dense double-sided assemblies. Three-dimensional X-ray laminography computes clear planar cross-sections through specific solder joint heights by blurring features above and below the focal plane of interest.
Quality control laboratories inspect hidden interconnects beneath quad flat no-lead packages and ball grid arrays without physically sectioning the circuit board.
Image Acquisition
Rotating X-ray sources and synchronized flat-panel detectors orbit a central axis aligned with target solder joint inspection areas. Geometric focus algorithms process dozens of tilted projection images to synthesize thin horizontal slices at precise vertical offsets through solder deposits. Adjusting mathematical reconstruction focal planes allows technicians to analyze voiding percentages inside multi-layer ball grid array joints layer by layer.
Advanced detector calibration routines correct for gain variations and scatter noise, generating high-contrast images of leadless component terminations.
Defect Detection
Inspection algorithms evaluate slice images to quantify internal solder void volumes and barrel fill percentages in plated through holes. Automated defect detection software flags geometric anomalies across complex solder profiles. Quantitative slice analysis replaces destructive micro-sectioning during root cause failure investigations.