Contact Component
Electromechanical contact provides the interface between high-density test electronics and the pads of a semiconductor wafer or circuit board. The vertical spring probe consists of a plunger, a barrel and an internal spring that allows for compliance during engagement. This design compensates for variations in pad height and ensures a consistent contact force across the entire array.
These pins are essential for high-volume production where reliability and ease of replacement are paramount.
Mechanical Operation
Compression of the plunger into the barrel creates the normal force required to pierce through surface oxides. In a vertical spring probe, the current usually travels through the barrel or directly through the plunger depending on the internal architecture. Precision machining ensures that the plunger moves smoothly without sticking or catching.
The choice of tip shape (such as a crown or point) is determined by the metallurgy of the target surface and the need to minimize witness marks.
Wear Factor
Life expectancy is measured in hundreds of thousands or millions of cycles before the spring fatigues or the plating fails. A vertical spring probe eventually develops high resistance due to the accumulation of solder transfer or environmental contaminants. Regular cleaning and electrical verification are performed to identify pins that are nearing their end of life.
When a probe card is refurbished, these individual pins can be replaced to restore the electrical performance of the entire test head.