Adhesion Value
Measuring the force required to separate a conductive foil from its insulating base material provides data on the reliability of the copper to resin bond. The mechanical peel strength is measured by pulling a standardized strip of copper at a constant angle and speed. It is typically reported in pounds per inch or newtons per millimeter.
Bonding Factor
Surface roughness of the copper foil is the primary contributor to the mechanical interlocking that holds the interface together. If the mechanical peel strength is too low, the traces may lift during the heat of soldering or the stress of component placement. Factors such as the resin cure state, the presence of contaminants and the chemical treatment of the foil all influence the final result.
Manufacturers often use oxide or silane treatments to enhance the connection between the smooth surfaces of high frequency laminates and the conductive layers.
Test Procedure
Standardized protocols like IPC-TM-650 define the conditions under which these measurements are taken. Testing occurs both in the as-received state and after thermal stress to ensure the bond remains stable. A failure where the resin remains on the copper is generally preferred over a clean separation at the interface.