Assessment Methodology
Experimental strain measurement protocols executed on populated circuit assemblies evaluate physical deformation induced by manufacturing and handling processes. Surface-mounted triaxial strain gauge rosettes measure surface microstrain during depaneling, connector attachment, heat sink mounting, and board insertion. Performing mechanical strain analysis identifies assembly steps that exceed material strain limits, preventing latent solder joint damage or ceramic component cracking.
IPC JEDEC 9704 establishes industry standard procedures for strain gage application and data analysis on printed circuit assemblies.
Defect Prevention
Board bending during automated assembly creates high tensile stresses in brittle solder joints. Exceeding microstrain thresholds leads to pad cratering, copper trace fracture, and internal layer dielectric cracking. Applying mechanical strain analysis during assembly process development isolates problematic tooling designs or manual handling procedures before high-volume manufacturing commences.
Measurement Protocol
High-speed data acquisition systems record dynamic strain responses across multiple rosette channels simultaneously. Derived strain parameters include principal strains, strain rates, and diagonal strain components calculated at peak deflection events. Test engineers compare recorded strain rate and strain magnitude values against empirical failure envelopes established for specific package types like ball grid arrays or surface-mount chip capacitors.
Process adjustments such as modifying support pin locations or reducing insertion force bring strain levels back within acceptable process boundaries.