Insulation Integrity
Electrical stress testing identifies insulation weaknesses in circuit assemblies by applying a potential difference larger than the rated operating voltage. Hi-pot testing measures the ability of an insulating material to prevent current flow between isolated conductors on a circuit board, providing a direct assessment of the isolation barriers. Engineers specify dielectric withstand voltage levels to ensure that a board can handle transient overvoltages without catastrophic breakdown.
This value is determined by the distance between traces and the thickness of the dielectric layers.
Testing Procedure
Test voltage application occurs between isolated conductors. During the measurement of dielectric withstand voltage, the potential is increased at a specified rate and held for a duration typically ranging from sixty seconds to several minutes. A leakage current threshold is set to detect insulation failure, which often appears as a sudden arc or spark.
The test is non-destructive if the insulation remains intact, but it can permanently damage a board with manufacturing defects like slivers or narrow clearances.
Safety Margin
Performance requirements ensure that the device remains safe for users under abnormal electrical conditions. Successful completion of dielectric withstand voltage testing confirms that the insulation system provides sufficient protection against electric shock and short circuits.