Potential Difference
Electrical contact between dissimilar metals in the presence of an electrolyte causes accelerated degradation of the less noble metal. Although galvanic corrosion is common in damp environments, its rate depends heavily on the difference in electrochemical potential between the contacting materials. Gold-plated pads on a printed circuit board that contact tin-plated component leads are particularly susceptible when exposed to condensation.
Electrochemical Reaction
Chemical pathways drive the dissolution of the anode while the cathode surface remains intact or receives a protective deposition. In printed circuit board assemblies, galvanic corrosion occurs when moisture acts as a bridge between copper and finishes like silver or tin. This reaction generates an electric current that speeds up the oxidation of the metal with the lower potential.
The resulting metallic salts can bridge adjacent conductors, which creates leakage currents or direct electrical shorts that cause circuit malfunction. Assemblies with fine-pitch traces are highly vulnerable to these conductive pathways because the distance between conductors is small.
Prevention Strategy
Design guidelines minimize metal combinations that have a high potential difference on exposed boards. Implementing conformal coatings or selecting compatible surface finishes prevents galvanic corrosion by blocking the electrolyte from reaching the metal junctions. Using nickel barriers between copper and gold layers also reduces the galvanic potential at the interface.