Expansion Offset
Strain gauge measurement errors arise when thermal expansion of the test substrate and temperature-dependent resistance shifts alter sensor output independent of mechanical load. Unintended electrical signal shifts known as thermal apparent strain occur when a strain gauge experiences temperature changes while bonded to a test surface. Differentiating mechanical strain from thermally induced resistance changes requires baseline thermal calibration curves.
Raw output signals from bonded strain sensors represent combined mechanical stress and thermal shift effects.
Polynomial Fitting
Data analysis software subtracts thermally induced resistance shifts from raw strain measurements using high-order polynomial correction equations. Quantifying thermal apparent strain during thermal cycling tests prevents false mechanical stress readings on printed circuit board components and solder joints. Test procedures record sensor output on unconstrained baseline coupons manufactured from identical printed circuit board laminate materials.
Polynomial curves fitted to baseline readings define correction factors for each temperature step. Subtracting baseline apparent strain values from operational test data yields true mechanical strain induced by thermal expansion mismatches or mechanical bending.
Uncompensated Margin
Inaccurate thermal baseline subtraction introduces severe errors into strain energy calculations near ball grid array solder joints. High thermal apparent strain values mask subtle mechanical strain events during thermal shock testing. Precise thermal correction retains measurement fidelity across wide environmental testing ranges.