Transient Strain Measurement Methods for In-Circuit Vacuum Test Fixtures

Dynamic triaxial strain rosette measurement across vacuum actuation isolates transient board bending, preventing latent solder fracture and pad cratering.

01.11.26 18 min

Contact

Electrical continuity reports confirm circuit connection across an in-circuit test fixture while masking the mechanical displacement that fractures surface-mount terminations beneath the board. Vacuum-actuated fixtures draw a bare or populated board onto spring-loaded test probes using atmospheric pressure differentials up to 85 kilopascals. This pressure creates concentrated mechanical bending moments across unsupported board spans, perimeter gaskets, and push-finger reaction points.

Solder joints crack under microsecond displacement spikes before functional test stations record a single electrical signature. Solder joint fracture surfaces examine as brittle intermetallic separation at the nickel-tin boundary under scanning electron microscopy, yet the test logs record complete electrical continuity at final station release. Solder cracks pass functional testing because mechanical probe force compresses severed pads against component metallization during electrical interrogation.

Mechanical strain measurement during fixture actuation quantifies these transient bending states before production boards enter volume manufacturing. Strain gauge instrumentation records physical board deformation during the exact physical transition where vacuum pulls the assembly downward against the probe field. IPC-JEDEC-9704 provides the testing framework for printed circuit board strain gauge testing, establishing boundary limits for mechanical displacement rates across manufacturing fixtures.

Transient strain measurement methods require triaxial strain gauge rosettes placed directly adjacent to high-risk package corners, high-speed multichannel data acquisition systems capturing sampling rates above 500 Hertz, and analytical reduction algorithms that calculate principal strains and strain rates.

Solder joints fractured across intermetallic boundaries maintain electrical contact under probe loading, producing passing electrical logs on mechanically destroyed assemblies.

Vacuum fixtures impose different boundary dynamics than pneumatic or manual clamshell systems. Clamshell presses deliver mechanical actuation via rigid push gates with defined stroke travel, whereas vacuum fixtures apply distributed face loading while perimeter rubber seals compress dynamically. This creates non-linear flexure cycles across the printed wiring board.

Pin density variations across the fixture base convert a flat board into a complex structural web under atmospheric draw-down. High-density ball grid arrays, small-pitch quad flat packages, and multilayer ceramic capacitors absorb these localized deformations directly through their solder fillets.

Precision machined aluminum housing sits beside an electronic substrate featuring visible gold wire bonding in a controlled manufacturing environment.

Package Sensitivity and Component Limits

Multilayer ceramic chip capacitors, ball grid arrays, and wafer-level chip-scale packages exhibit distinct structural failure thresholds under transient mechanical deformation. Ceramic capacitors crack internally along the terminal termination margin when tensile strain exceeds 500 microstrain, producing catastrophic electrical failure or latent dielectric breakdown during customer service. Ball grid array packages withstand moderate spherical shear but fracture across outermost corner solder joints when package warpage decouples from board flexure.

Wafer-level chip-scale packages concentrate all board displacement directly into solder balls without the mechanical compliance of an intermediate substrate.

Allowable transient strain thresholds scale downward as package physical dimensions expand and dielectric layers thin. The allowable principal strain limit drops systematically as the component body length increases and as the calculated strain rate escalates during actuation. A fixture drawing down at 1500 microstrain per second across an 0805 capacitor requires tighter mechanical limits than an actuation sequence generating 50 microstrain per second across the same component body.

Dynamic transient analysis evaluates both magnitude and velocity to prevent package shearing.

Mechanical Fragility Limits and Failure Modes Across Common Surface Mount Geometries Under Board Flexure
Package Family Body Size (mm) Strain Threshold (Microstrain) Critical Rate (Microstrain/Sec) Primary Failure Mode
MLCC 0402 1.0 x 0.5 800 10,000 Internal 45-degree dielectric margin crack
MLCC 0805 2.0 x 1.25 600 7,500 End termination metallurgical separation
MLCC 1210 3.2 x 2.5 400 5,000 Through-body ceramic fracture shorting rails
Fine-Pitch BGA 15 x 15 500 5,000 Intermetallic fracture at component pad interface
Large BGA 35 x 35 350 3,500 Corner pad cratering beneath copper land
WLCSP 5 x 5 400 4,000 Silicon die chipping and trace detachment

IPC-JEDEC-9704 defines explicit equations for calculating allowable principal strain based on board thickness, component dimensions, and observed strain rate. Thinner circuit cards flex across steeper radii, generating elevated surface shear on external copper layers. Component failures materialize within the laminate resin matrix beneath copper pads, an irreversible defect termed pad cratering.

Pad cratering exposes trace copper to tensile pull-out, severing internal routing traces connected to package vias without fracturing the solder ball itself.

The fixture vendor typically claims that perimeter vacuum gasket profiles distribute atmospheric loads uniformly across the assembly during cycle pull-down.

Vacuum

Fixture actuation begins when the pneumatic control circuit evacuates the chamber between the fixture bed and the assembly under test. Solenoid valves open the main suction channel, evacuating several liters of air within milliseconds. Atmospheric pressure presses the board downward against the spring-probe array.

Reaction forces across hundreds or thousands of spring probes push upward simultaneously. Probe arrays present uneven counter-force resistance across the circuit card when high-speed test nets, dense digital buses, and analog nodes concentrate hundreds of test pins beneath single functional circuit partitions.

Atmospheric pressure acts as a uniform surface pressure load, yet probe resistance concentrates as an array of point forces. Where four hundred probes interface beneath a multi-core microprocessor, the probe field pushes upward with upward reaction forces exceeding one hundred newtons. The adjacent memory bank or power conversion area may host ten pins across an equivalent board area.

This force mismatch produces localized bending moments across component footprints positioned between dense and sparse probe clusters.

Several insulated cables pass through a toroidal current transformer mounted next to an integrated circuit on a dark printed circuit board.

Gasket Compression Dynamics

Perimeter vacuum sealing relies on closed-cell cellular silicone, neoprene, or polyurethane gaskets placed along the edges of the printed wiring board. Gaskets require substantial initial compression force before creating an airtight seal against atmospheric leakage. Closed-cell silicone gaskets deform under non-linear stress-strain relationships, presenting high initial stiffness followed by cellular collapse.

As the vacuum pressure deepens, the outer frame of the circuit card pulls downward ahead of the board center, inducing initial spherical dishing.

Unequal perimeter gasket compression tilts the circuit board across the fixture plane before probe tips engage target pads. Single-sided gasket compression sequences force the outer edge down while the board center stays suspended against high-force switch probes. Dual-stage vacuum fixtures exacerbate this profile by applying two distinct evacuation chambers to actuate different probe banks sequentially.

Mechanical strain cycles reverse direction during evacuation, turning compressive surface strain into severe tensile elongation across component topsides within fifty milliseconds.

  1. Chamber Evacuation Cycle draws atmospheric air from beneath the board panel, generating uniform downward pressure up to 85 kilopascals across unsupported laminate surfaces.
  2. Peripheral Gasket Collapse compresses the outer cellular elastomer boundary, driving the edge down while unprobed sectors follow the elastomeric stroke.
  3. Probe Array Resistance delivers hundreds of concentrated point loads as high-travel test pins depress into internal spring cavities.
  4. Stop Pin Impact halts vertical panel travel abruptly when the board bottom contacts rigid metal support pillars positioned across the bottom plate.
  5. Atmospheric Equalization Shock exhausts the vacuum chamber via high-flow exhaust ports, allowing spring probes to kick the assembly upward against atmospheric resistance.

Actuation profiles capture four distinct mechanical phases: sealing onset, free flexure travel, probe landing resistance, and hard-stop bottoming. Transient strain graphs illustrate that the maximum strain peak rarely occurs during the steady-state vacuum hold. Maximum peak strain occurs during the landing phase when the board strikes rigid bottom support posts, or during vacuum dump when compressed probe springs snap upward against the rebounding circuit card.

IPC-JEDEC-9704 specifies that manufacturing fixture strain rates must calculate principal values from simultaneous three-axis rosette records to prevent axis misidentification.

Support push-pins prevent localized dishing, but incorrect push-pin placement magnifies board strain rather than alleviating it. A support pin placed ten millimeters away from a dense probe cluster forms an anvil, bending the circuit card over its hardened tip as atmospheric pressure continues downward deflection. Vacuum fixtures require calculated support-to-probe force balance across every board quadrant.

Tooling errors generate severe transient strain profiles during normal manufacturing operations.

Eliminating support pins under dense probe arrays cracks BGA solder balls across first-run qualification panels.

Sensor

Strain gauge instrumentation requires careful sensor selection, adhesive attachment, and electrical wiring configurations to measure dynamic transient strain on printed circuit boards accurately. Uniaxial gauges capture deformation in one orientation, providing incomplete measurement data along complex multi-axis bending planes. Multi-axis surface flexure demands triaxial strain gauge rosettes containing three distinct measurement grids arranged in rectangular or delta geometries.

Rectangular rosettes utilize 0-degree, 45-degree, and 90-degree grid orientations, resolving complete planar strain tensors into maximum principal strain, minimum principal strain, and principal angle.

Grid selection governs both mechanical compliance and signal distortion. Large measurement grids integrate strain across wide surface distances, attenuating localized strain concentrations present near solder pads. Small gauge grids accurately resolve localized stress fields near component corners.

A gauge grid length of 0.38 millimeters or 0.76 millimeters captures localized gradient fields without spatial averaging distortion across surface laminate layers.

A metallic probe hovers over a detailed integrated circuit package positioned on a dark circuit board substrate during manufacturing.

Rosette Placement Criteria

Strain rosettes must sit at the locations of maximum structural vulnerability. Component corners experience maximum thermal and mechanical shear stress, making package perimeter corners the prime measurement target. For rectangular ball grid arrays and quad flat packages, rosettes mount along the outer corner package edge with one grid aligned perpendicular to the package perimeter.

Multi-layer ceramic capacitors demand rosettes placed directly adjacent to the solder fillet edge along the component longitudinal centerline.

IPC-JEDEC-9704 defines strict clearance guidelines governing gauge boundary distance from component solder terminations. Gauges positioned farther than 1.5 millimeters from a solder pad edge fail to register the steep strain gradient generated as the rigid package resists board bending. Mounting gauges too close to the fillet risks mechanical interference with component solder joints or chemical contamination of the gauge backing from residual soldering flux.

Surface preparation requires careful mechanical abrasion of solder mask layers using micro-abrasive media, followed by solvent cleaning with isopropyl alcohol to guarantee structural adhesion without damaging copper traces buried beneath outer epoxy layers.

Electrical and Mechanical Parameters of Triaxial Rosette Gauges for Printed Wiring Board Testing
Parameter Subminiature Triaxial Standard Triaxial Stacked Triaxial
Grid Length (mm) 0.38 0.76 1.00
Nominal Resistance (Ohms) 120 or 350 120 or 350 350
Gauge Factor Accuracy ±1.0% ±0.5% ±0.5%
Thermal Compensation Target FR-4 (13-16 ppm/°C) FR-4 (13-16 ppm/°C) FR-4 (13-16 ppm/°C)
Excitation Voltage (V RMS) 1.0 to 1.5 1.5 to 2.0 1.0 to 2.0
Maximum Linear Strain Range ±30,000 microstrain ±50,000 microstrain ±50,000 microstrain
Planar Configuration Planar layout Planar layout Stacked three-layer

Stacked rosettes place three independent grid layers directly above each other on a single polymer backing film, locating all three measurement grids at the exact same planar coordinate point. Planar rosettes arrange the three measurement grids side by side on a flat film. Planar configurations produce minor spatial offset errors across high strain gradients, while stacked rosettes exhibit higher bending stiffness and increased thermal dissipation resistance.

Adhesive selection determines measurement reliability across transient flexure cycles. Cyanoacrylate adhesives provide fast bonding cycles suitable for quick fixture qualifications, but experience room-temperature creep under high-humidity production environments. Two-component heat-cured epoxy adhesives maintain structural shear transfer across high-strain cycles without adhesive yield or viscoelastic slippage.

Lead-wire attachment introduces mechanical loading and electrical noise into the acquisition system. Thin copper hookup wires pull on miniature gauge solder tabs during vacuum actuation, shearing tabs away from the polymer backing. Wiring channels routed across the circuit board must bond securely to the laminate with low-modulus silicone adhesive, creating mechanical strain relief loops before the wiring bundle routes through the fixture vacuum sealing frame.

Gauge installation across high-density circuit assemblies requires micro-soldering tools to secure fine-gauge lead wires without bridging adjacent component terminals.

Sampling

Transient board deformation during vacuum actuation occurs within narrow millisecond time windows. Quasistatic measurement techniques that average strain data over seconds miss rapid displacement spikes caused by mechanical snap-through, probe impact, and vacuum dump transients. Complete transient capture demands high-speed simultaneous-sampling analog-to-digital converters capable of processing multi-channel rosette data without phase delay.

Sampling rate selection directly determines measured peak amplitude and calculated strain rate. Analog signals low-pass filtered or digitized at low sampling frequencies attenuate peak strain values, misrepresenting dangerous mechanical transitions as compliant movements. Nyquist criteria establish the mathematical floor for frequency recreation, but transient strain rate capture demands oversampling by orders of magnitude to compute accurate derivative curves.

This laboratory scene shows a copper busbar secured by multiple test clamps and being touched by a precision probe, indicating an electrical measurement process.

Acquisition Bandwidth Requirements

Vacuum fixtures execute full mechanical pull-down within 80 to 250 milliseconds, with transient shock oscillations occurring at resonant frequencies between 200 Hertz and 2 kilohertz. A sampling rate of 500 Hertz records data points every 2 milliseconds, skipping structural vibration peaks entirely. Sampling at 10 to 50 kilohertz per channel captures rapid wave propagation across FR-4 laminates as vacuum seals seat against fixture tooling plates.

High sample rates enable precise derivation of transient strain rate, measured as change in microstrain divided by change in seconds.

Strain rate calculations are sensitive to high-frequency instrumentation noise. High-frequency electrical noise from nearby vacuum pump motors, switched solenoid coils, and test instrumentation couples onto unshielded gauge lead wires. Differentiating noisy displacement signals magnifies high-frequency variance into false strain rate spikes.

Anti-aliasing analog filters paired with digital Bessel or Butterworth low-pass filters set to 1 kilohertz cutoffs isolate structural signals from industrial electrical interference.

Bandwidth settings below one kilohertz truncate peak strain amplitudes during vacuum pull-down, producing false compliance readings on high-risk packaging.

Wheatstone bridge completion circuitry configuration alters measurement precision and signal-to-noise ratio. Quarter-bridge Type I circuits use one active gauge grid paired with three internal precision bridge resistors. This arrangement requires three-wire lead connections to cancel parasitic wire resistance changes caused by environmental temperature swings within the sealed vacuum chamber.

Half-bridge and full-bridge configurations provide superior common-mode noise rejection, but multi-axis rosette measurement across tight component corners restricts practical sensor topologies to quarter-bridge installations.

Excitation voltage selection introduces a technical balance between signal resolution and thermal drift. Higher excitation voltages yield larger output signals per microstrain, increasing system signal-to-noise performance. High excitation across tiny gauge foils mounted to thermally insulating glass-epoxy printed wiring boards produces internal resistive self-heating.

Localized temperature elevation alters the gauge factor and generates apparent thermal strain drift that masks real mechanical movement. Excitation levels must stay between 1.0 and 1.5 volts direct current to maintain thermal stability on standard FR-4 laminates.

  • Bridge Excitation Drift occurs when excessive bridge current generates localized internal heating within subminiature gauge foil grids on non-conductive glass-epoxy substrates.
  • Channel Phase Asymmetry results from multiplexed data acquisition cards reading rosette grids sequentially rather than through simultaneous sample-and-hold hardware.
  • Cable Capacitance Losses degrade measurement accuracy over long wiring runs passing out through vacuum feedthrough manifolds without intermediate signal conditioning.
  • Ground Loop Coupling injects sixty-cycle mains noise into high-gain differential amplifiers when fixture vacuum frames bond to distinct protective earth points.

Simultaneous sample-and-hold architectures prevent inter-channel time skew across the three rosette grids. Multiplexed acquisition boards that sweep across channels introduce phase shifts between grid recordings. Calculating principal strain from phase-shifted measurements distorts both maximum strain magnitude and calculated principal orientation angles during rapid transient motion.

A fixture operator may claim that low-speed logging across a digital multimeter proves the fixture mechanical stroke is completely benign.

Reduction

Raw strain gauge records register localized linear deformation along the discrete axes of the three sensing grids. Evaluating structural risk requires converting these three raw channels into invariant mechanical tensors. Triaxial rectangular rosettes supply three simultaneous orthogonal strain values: epsilon a (0 degrees), epsilon b (45 degrees), and epsilon c (90 degrees).

Mathematical transformation maps these directional readings into maximum principal strain, minimum principal strain, and maximum shear strain across the printed board surface plane.

Maximum principal strain defines the largest normal tensile strain acting on the surface layer, regardless of component geometric orientation. Brittle solder joints and ceramic bodies fail primarily under tensile cleavage stress, rendering maximum principal strain the decisive variable for mechanical structural qualification. The reduction sequence processes every discrete time step independently, constructing a continuous timeline of principal strain throughout the fixture vacuum engagement cycle.

A technician in blue overalls and nitrile gloves uses a precision probe on a green plastic part inside a dark production facility.

Tensorial Mathematics for Rectangular Rosettes

Mohr’s circle equations govern planar strain transformations for 0-45-90 degree rectangular rosette geometries. The intermediate normal strain components and shear strain resolve directly from the three measured grid channels:

Normal strain in the X direction equals epsilon a.

Normal strain in the Y direction equals epsilon c.

Engineering shear strain equals two times epsilon b minus epsilon a minus epsilon c.

The maximum principal strain (epsilon 1) and minimum principal strain (epsilon 2) calculate through the classical planar transformation equation:

epsilon 1, 2 = ((epsilon a + epsilon c) / 2) ± (((epsilon a – epsilon c) / 2)^2 + (epsilon b – (epsilon a + epsilon c) / 2)^2)^(1/2)

The principal angle (theta) defines the spatial orientation of maximum principal strain relative to the primary sensor grid axis:

theta = (1 / 2) arctan((2 epsilon b – epsilon a – epsilon c) / (epsilon a – epsilon c))

Calculating the principal angle reveals whether board flexure originates from perimeter gasket pull-down, support pin reaction, or asymmetrical probe push-back. If the calculated angle rotates wildly across the actuation stroke, the board experiences non-proportional dynamic twisting. Static uniaxial strain analysis fails entirely under non-proportional twisting conditions.

A black surface mount integrated circuit chip is connected by fine braided copper wires to a flexible ribbon cable on a green printed circuit board.

Metric Selection and Diagonal Strains

IPC-JEDEC-9704 defines two primary analytical metrics: maximum principal strain and diagonal strain. Diagonal strain isolates mechanical deformation acting across component corners, projecting surface strain along the diagonal axis of the component package body. For ball grid array packages, diagonal strain correlates closely with corner solder ball peeling stress.

Solder balls positioned along package corners experience localized tensile prying moments when the board curves along the diagonal package centerline.

Worked Calculation of Triaxial Rosette Metric Reduction Across a Vacuum Stroke Transition
Time (ms) Grid a (0°) Grid b (45°) Grid c (90°) Principal 1 (Tensile) Principal 2 (Comp) Strain Rate (µe/s)
0.00 0 0 0 0 0 0
25.00 45 85 60 98 7 3,920
50.00 120 290 180 335 -35 9,480
75.00 210 510 310 588 -68 10,120
100.00 180 380 240 436 -16 -6,080
125.00 150 310 200 354 -4 -3,280

Strain rate computation requires taking the numerical derivative of the principal strain history with respect to time. Point-to-point numerical differentiation of digitized strain data amplifies signal quantization steps into massive mathematical noise spikes. Reliable reduction algorithms employ polynomial smoothing filters, such as five-point or nine-point Savitzky-Golay filtering arrays, to extract valid strain rates without attenuating legitimate structural shock pulses.

Strain rate establishes the mechanical damage boundary on IPC-JEDEC-9704 failure envelopes. At elevated strain rates, solder alloys transition from ductile plastic deformation to brittle intermetallic cleavage, dropping allowable strain limits by more than fifty percent.

Does the strain rate envelope remain valid when circuit card laminate materials transition from standard glass-epoxy to high-speed low-loss resins?

High-frequency laminates, such as ceramic-filled hydrocarbon and modified polyimide resins, exhibit significantly higher flexural moduli and lower resin fracture toughness than standard FR-4 materials. Brittle micro-cracking occurs within these specialized substrates at principal strains well below published industry envelope limits, requiring custom qualification curves derived from coupon-level mechanical bending tests.

Uncalibrated software algorithms that substitute simple algebraic averages for true tensorial principal reduction leave critical mechanical failure modes unidentified.

A small circuit board assembly with header pins is immersed in a solder pot containing molten solder on an electronics workbench.

Qualification

Fixture qualification formalizes strain measurement methods into a clear technical baseline, separating conforming manufacturing fixtures from destructive tooling before volume production begins. The qualification process tests an assembled, fully instrumented functional panel through repeated cycles of vacuum engagement, steady-state hold, and chamber venting. A qualification run evaluates multiple actuations across each test nest to identify mechanical variance caused by gasket relaxation, seal degradation, and probe spring fatigue.

Fixtures failing strain envelope limits require structural alterations before sign-off. Remediation techniques alter the mechanical boundary conditions within the fixture chamber. Structural stiffener bars, added support push-pins beneath dense component sectors, vented vacuum gaskets, and reduced probe spring forces systematically lower transient strain magnitudes.

Qualification documentation compiles all raw rosette histories, tensorial reduction plots, and IPC-JEDEC-9704 envelope overlays into a technical dossier attached directly to the fixture serial record.

  1. The test engineer bonds calibrated triaxial strain rosettes adjacent to every package exceeding size limits or positioned within two millimeters of push-pins.
  2. The technician connects lead wires to a simultaneous multi-channel bridge amplifier operating with excitation voltages limited to 1.5 volts direct current.
  3. The operator records five baseline calibration sweeps at zero mechanical load to confirm electrical bridge balance and quantify background instrumentation noise.
  4. The fixture actuates through ten consecutive production vacuum cycles, recording dynamic strain records across pull-down, dwell, and exhaust phases.
  5. The analysis routine reduces raw directional channels into maximum principal strain and computes dynamic strain rate curves across all rosettes.
  6. The quality engineer plots derived principal values against component-specific IPC-JEDEC-9704 limits to confirm zero boundary line breaches across all cycles.

A qualification dossier serves as commercial protection for sourcing practices managing contract manufacturing organizations. If an offshore assembly plant modifies push-pins or alters vacuum pull-down solenoids to accelerate cycle time, recorded strain profiles shift upward. When field failures emerge from intermetallic fatigue or pad cratering, the baseline qualification report serves as contractual evidence proving whether failures stem from component defects or unapproved tool alterations on the factory floor.

Contractual fixture acceptance clauses require zero strain exceedances across ten consecutive cycles at full operational vacuum level, voiding commercial sign-off when transient records register outside defined boundary envelopes.

Nomenclature

Test Fixture Qualification

Fixture Verification ~ Physical inspection of a bed of nails array confirms alignment accuracy between probe tips and contact pads on a printed circuit board.

Triaxial Strain Rosette

Measurement Geometry ~ Three resistive foil sensors mounted on a single carrier quantify surface deformation across multiple directions simultaneously.

Pad Cratering

Mechanical Separation ~ A fracture occurring at the interface between the copper foil and the epoxy resin base material identifies pad cratering.

Maximum Principal Strain

Strain Tensor Metric ~ Biaxial strain states measured across a deformed circuit board resolve mathematically into orthogonal normal components, where the largest tensile value represents the maximum principal strain.

Triaxial Strain Gauge

Multi-Axis Sensing ~ Sensor configuration comprising three independent measurement elements oriented at specific angles to measure the full strain field of a surface.

Mechanical Strain

Deformation Proportion ~ Dimensional variance within a printed circuit board substrate describes the quantitative relationship between internal displacement and original geometry when external forces apply.

Intermetallic Fracture

Structural Rupture ~ Mechanical separation occurring at the boundary layer between bulk solder and the printed circuit board pad finish marks a critical point of failure in electronic assemblies.

Solder Joint Brittleness

Mechanical Fracture ~ The structural vulnerability of intermetallic layers within surface mount technology assemblies governs solder joint brittleness under thermal and mechanical shock conditions.

Mohr Circle Transformation

Stress Analysis ~ Graphical projections of normal and shear components allow for the calculation of principal stresses at any plane orientation within a material.

IPC/JEDEC-9704

Strain Measurement ~ Mechanical testing protocols determine the risk of solder joint fractures during circuit assembly operations such as screw fastening or connector insertion.

Strain Rate

Mechanical Deformation ~ Velocity defines the temporal progression of structural displacement within a solid material under load.

Shear Strain

Geometric Distortion ~ Deformation within a body occurs when parallel planes shift relative to one another while maintaining separation distances.

What the firm knows, published